- 3.2 V open circuit voltage
- operating voltage (depending on conditions) typically above 2.5 V
- nominal capacities spanning the 0.3 to 33.0 Ah range
- compliance with numerous military standards
| LM spiral cells |
LM 17130 |
LM 22150 |
M 49* |
M 52 HR* |
M 56* |
| Size |
1/3 A |
1/3 sub-C |
3/4 sub-C |
C |
5/4 C |
| Open circuit Voltage |
3.2 V |
3.2 V |
3.2 V |
3.2 V |
3.2 V |
| Nominal voltage |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
| Nominal capacity (drain; 2,0 V cut off) |
0.5 Ah (4.5 mA) |
0.9 Ah (40 mA) |
1.6 Ah (80 mA) |
4.8 Ah (150 mA) |
6.7 Ah (150 mA) |
| Max. recom. Cont. Current |
0.3 A |
0.4 A |
0.3 A |
2.0 A |
2.5 A |
| Operating temp. Range |
-40/+70°C |
'-40/+70°C |
'-40/+70°C |
'-40/+70°C |
'-40/+70°C |
| Outside diameter max |
16.7 mm |
22.8 mm |
22.5 mm |
26.2 mm |
26.2 mm |
| Height max |
16.6 mm |
17.3 mm |
32.0 mm |
51.5 mm |
61.5 mm |
| Weight |
8 g |
15 g |
24 g |
59 g |
70 g |
| Transport |
Non restricted |
Non restricted |
Class 9 |
Class 9 |
Class 9 |
| |
|
|
|
|
|
| LM spiral cells |
M 19* |
LM 33550 |
M 20* |
M 20 HR* |
M 24 HR* |
M 62* |
| Size |
"Short" D |
D |
D |
D |
DD |
"Big" DD |
| Open circuit Voltage |
3.2 V |
3.2 V |
3.2 V |
3.2 V |
3.2 V |
3.2 V |
| Nominal voltage |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
| Nominal capacity (drain; 2,0 V cut off) |
10.3 Ah (450 mA) |
12.0 Ah (250 mA) |
12.6 Ah (150 mA) |
11.5 Ah (0.5 A) |
20.0 Ah (2.0 A) |
33.0 Ah (1.6 A) |
| Max. recom. Cont. Current |
3.0 A |
4.0 A |
3.5 A |
4.0 A |
6.0 A |
6.0 A |
| Operating temp. Range |
-40/+70°C |
-40/+70°C |
-40/+70°C |
-40/+70°C |
-40/+70°C |
-40/+70°C |
| Outside diameter max |
33.5 mm |
34.2 mm |
34.2 mm |
34.2 mm |
33.5 mm |
42.5 mm |
| Height max |
58.5 mm |
61.4 mm |
61.5 mm |
61.5 mm |
110.5 mm |
133.0 mm |
| Weight |
105 g |
120 g |
117 g |
117 g |
201 g |
355 g |
| Transport |
Class 9 |
Class 9 |
Class 9 |
Class 9 |
Class 9 |
Class 9 |
| |
|
|
|
|
|
|
* FRIWO cells