- Operating voltage typically above 3.5 V
- 4.2 V end of charge voltage
- UL recognized cells
- Some cell and battery pack models are non-restricted for transport
| Dimensions |
MP 144350 |
MP 174565 Integration |
MP 174865 |
MP 174865 IS |
| Thickness (1) |
14.5 mm max. |
19.5 mm max. |
19 mm max. |
19 mm max. |
| Width |
43 mm max. |
45 mm max. |
48 mm max. |
48 mm max. |
| Height |
50 mm max. |
68.35 mm max. |
65 mm max. |
65 mm max. |
| Typical weight (2) |
68 grams |
105 grams |
124 grams |
124 grams |
| Nominal Voltage (3) |
3.75 V |
3.75 V |
3.75 V |
3.65 V |
| Rated Capacity (4) |
2.6 Ah |
5.0 Ah |
5.3 Ah |
4.8 Ah |
| |
|
|
|
|
| Dimensions |
MP 176065 Integration |
|
|
|
| Thickness (1) |
19.2 mm max. |
|
|
|
| Width |
60 mm max. |
|
|
|
| Height |
68.35 mm max |
|
|
|
| Typical weight (2) |
146 grams |
|
|
|
| Nominal Voltage (3) |
3.75 V |
|
|
|
| Rated Capacity (4) |
7.0 Ah |
|
|
|
| |
|
|
|
|
(1) 100% charged, uncycled, unsleeved, unlabelled bare cells
(2) unsleeved, unlabelled cells
(3) C/2 current drain, +20°C, at mid-discharge
(4) uncycled cell charged at C/2 rate up to 4.2 V, followed by 1 to 4 hours of rest at +20°C, and discharged at +20°C at a constant rate of C/5, down to 2.5 V
Maximum discharge current
Up to 2C continuous in the 0/+60°C range. Up to C/5 in the -50/0°C range.
Up to 4C in pulse conditions (consult Saft for specific conditions)
The electronic protection circuit within single cell 1s1p batteries limits the discharge current to 5 A maximum.
Charge method
Constant current / Constant voltage (CCCV)
Charging Current
Up to 1 C-rate
Operating temperature ranges
Charge : -20 / +60°C
Discharge : -50 / +60°C
Transport assignment
MP 144350 & MP 174565 Integration Non-restricted as long as the battery pack features no more than 10 component cells
MP 174865 & 176065 Integration Single cell and multi cell batteries are restricted (Class 9 assignment)
MP 174865 IS - Non-restricted (Class T6 assignment)